What winter here does to a heat pump
Your furnace or heat pump here runs seven months a year, October through April, longer than it runs cooling in any house in this county. That alone makes heating the season to plan around. A standard heat pump loses ground twice as it gets cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it often needs backup heat to make up the difference. The average overnight low here in December, January and February is 24°F, under both marks. And it is not a few nights a year. The overnight low falls to freezing or below about 110 nights a year here, close to half the nights the heat is even running. Every one of those nights, a standard heat pump is working below both the 40°F and 35°F marks.
That does not mean a heat pump will leave you cold. The cold-climate heat pumps built to ENERGY STAR's standard are tested to make real heat at 5°F, not just at 47°F, and in field testing over two winters, backup heat covered only a small share of the output between 0°F and 35°F. Running on backup alone was rare even above 0°F. That matters here because 0°F only happens about four nights a year. The other 106 nights at or below freezing sit well inside the range a cold-climate heat pump is built to handle without leaning on backup heat. A standard heat pump without that rating is a different machine on those same nights, and backup heat makes up more of its work.