What the cold here does to a heat pump
Winter here is long and it gets genuinely cold. The heat runs eight months a year, October through May, and the overnight low averages 20°F across December, January and February. About 130 nights a year dip to freezing or below, over half the nights in the heating season. Seven of those nights hit 0°F.
A standard heat pump starts losing ground before it gets anywhere near that cold. Below 40°F it puts out less heat than its rating says, and below about 35°F it typically needs backup heat to make up the difference. Both marks sit well above this county's 20°F average low. Every single night at or below freezing here, all 130 of them, falls below both marks. That is not an occasional cold snap. That is most of a Kosciusko County winter.
There is a version built for this. A heat pump with the ENERGY STAR Cold Climate mark has to prove it still makes at least 1.75 units of heat per unit of electricity at 5°F and holds onto 70 percent of its 47°F capacity at that temperature, checked by outside testing. In field tests of prototype cold-climate models running in real homes over two winters, backup heat covered only a small share of the load between 0°F and 35°F, and the system running on backup alone was rare even above 0°F. A standard heat pump is not built for this county's lows. A cold-climate one is tested against them.