Electricity here runs 14.77 cents per kilowatt-hour
Indiana households paid that rate in 2024. A heat pump runs on electricity for both heating and cooling, so that rate applies to the system year round, not just in summer.
Takes about a minute. No obligation.
Indiana households paid that rate in 2024. A heat pump runs on electricity for both heating and cooling, so that rate applies to the system year round, not just in summer.
Two heat pumps can heat the same house and cost different amounts to run at that rate. When you compare models for this job, the efficiency numbers matter as much as the price tag.

NOAA nClimDiv, 1991–2020 normals
Johnson County asks real work of a heat pump, with winter lows averaging 23°F and summer humidity pushing the other way.
Pick a unit built to handle both ends of that range, not just whichever one is cheapest to install.



Ask to see the HSPF2 and SEER2 numbers side by side for any unit you're considering, not just the price to install it. At 14.77 cents per kilowatt-hour, the difference between a mid-range heat pump and a high-efficiency one shows up on every bill, winter and summer both. A contractor quoting a system for this job should be able to walk you through those ratings and what they mean for a house this size. If they can't, that's a sign to get a second quote.
Heat here runs October through May, eight months out of the year. September is the last quiet month before that starts. Getting a new heat pump in before the first cold snap means a proper install, time to size it right, and no space heaters while you wait on an emergency appointment.
Find a contractor
A heat pump in Johnson County runs most of the year, through winter mornings near 23°F and summer days heavy with humidity. That's the two storms and 39 wind events on record don't touch it, but the steady grind of year-round heating and cooling does. Fewer extremes to fight means a well-built unit can last out its years without being pushed past what it's rated for. That's the case for picking one built to handle both ends of the range, not the cheapest to install. A reliable system here is doing real work most months, and it should be sized and rated for that, not just for the mildest days.
A heat pump loses capacity as the outdoor temperature drops, and at some point it needs help, either from electric resistance coils built into the air handler or from a furnace it's paired with in a dual fuel setup. Ask what kicks in, at what temperature, and what that costs to run compared to the heat pump itself. A system with no good answer here will lean on expensive backup heat more often than it should.
Contractors can quote the same tonnage and mean very different things by it. Sizing should come from a load calculation on the actual house, the windows, the insulation, the layout, not a guess based on square footage or whatever the old system was. A unit sized too large short cycles and never dehumidifies properly. One sized too small runs constantly and still can't keep up on the coldest days. Ask to see the calculation, not just the number it produced.
Whatever is replaced has to come out, and that part matters more with a heat pump than with a straight air conditioner. The old outdoor unit holds refrigerant that has to be recovered properly, not vented, so that job goes to a licensed contractor rather than a hauling crew. If the old system was a gas furnace paired with an AC, the furnace either gets decommissioned or stays as backup heat in a dual fuel setup, and that decision should happen before install day, not after. If there's an old line set running to the house, a contractor may reuse it or may tell you it's the wrong diameter for the new unit and needs replacing. Ask what happens to the old equipment and whether anything from it is staying behind.
Install day starts with the old equipment coming out, then the new outdoor unit gets set on its pad and the air handler or coil goes in wherever the old one sat. The line set gets connected, pressure tested, and pulled down to a vacuum before any refrigerant moves, because trapped air and moisture in the lines will cause problems later. Electrical work is its own step. A heat pump draws differently than a straight air conditioner, especially with backup heat built in, so the breaker and wiring get checked against what the new unit actually needs, not what the old one used. Once it's running, a tech checks refrigerant charge, airflow across the coil, and that the thermostat is actually talking to the system correctly, including any backup heat settings. A heat pump has more to configure at the thermostat than a furnace and AC pair did, since it's managing both heating and cooling through one set of settings. Expect the crew to run it in both modes before they leave, not just confirm it powers on.
