Electricity here runs 21.08 cents a kilowatt-hour
Porter County pays more for power than most of the country. A heat pump runs on electricity for both heating and cooling, so that rate applies every time it cycles on, all year.
Takes about a minute. No obligation.
Porter County pays more for power than most of the country. A heat pump runs on electricity for both heating and cooling, so that rate applies every time it cycles on, all year.
When power costs this much, the difference between a heat pump that runs efficiently and one that doesn't shows up on every bill it generates. The unit you install is the one you're stuck paying to run.

NOAA nClimDiv, 1991–2020 normals
Your old furnace or AC doesn't just vanish when the new system goes in.
Whoever installs your heat pump has to disconnect it, remove it, and deal with what's inside it, especially if it runs on refrigerant.




Porter County falls under zone 5A in the 2021 energy code, a cool zone where heating carries more of the load than cooling. Any split-system heat pump installed here has to meet the federal minimums that went into effect for units built from January 1, 2023 on: at least 14.3 Btu of heat moved per watt-hour over the summer, and at least 7.5 Btu per watt-hour over the winter. That sets a floor. It doesn't pick the unit for you, but it rules out anything built to a lower standard. Whoever installs your system has to work within that rule, not around it.
At that rate, an efficient heat pump earns its keep here faster than it would somewhere with cheaper power. Ask whoever quotes the job to walk you through the efficiency ratings on the units they're proposing, not just the price to install them.
Find a contractor
Sizing the system is what decides most of what happens after that. A unit too big for the house will short cycle, kicking on, blasting the space, and shutting off before it pulls moisture out of the air or settles into a steady rhythm. Too small, and it runs flat out without catching up, pushing wear onto the compressor long before it should. Getting that right takes a load calculation on the house itself, not a guess based on the last system that sat there. Beyond that, the ductwork matters as much as the unit bolted to it. A heat pump moves a different volume of air than a furnace and AC pair did, and ducts sized for the old equipment can choke the new one or leave rooms short. Line set length and placement of the outdoor unit factor in too. Longer refrigerant runs and more joints mean more places a connection can be brazed wrong. None of this shows up on the unit's label. It shows up in how the job gets planned before anyone touches a wrench.
Every heat pump carries a rating for cooling and a separate one for heating. Some units chase a strong cooling number while their heating performance drops off, which matters when the compressor has to work through cold weather, not just warm. Ask for both numbers, not the one that looks best on paper.
A heat pump pulls heat from outside air, and that gets harder as the air gets colder. Every unit has a point where its output starts dropping off, and a capacity chart showing performance at low temperatures tells you more than a single efficiency number. Some systems hold up better in the cold than others built to the same minimum rating.
The rating on the label, whether it's listed as an efficiency number for cooling or one for heating, is measured output divided by energy used. A higher number means the unit moves more heat per watt of electricity it draws, not that it heats or cools faster. Two systems can feel the same walking into a room and still cost very differently to run, because that difference lives in the compressor and how hard it has to work to hit the temperature you set. That rating is also measured under specific test conditions, so it won't match what you see exactly, but it tells you how the unit is built to perform relative to another one. A unit with a low rating isn't broken or undersized. It's just going to draw more power to do the same job, every time it cycles on, for as long as you own it.
Installation starts with pulling out what's there now, and the rest of the day follows a set order. The outdoor unit gets set on a pad or bracket, leveled, and the indoor coil or air handler goes in wherever the old one sat, sometimes with modifications if the new equipment doesn't match the old footprint. Line sets get run between the two, brazed at every joint, then pressure tested to make sure those joints hold before any refrigerant goes in. The system gets evacuated to pull moisture and air out of the lines, because either one left behind will damage the compressor over time. Electrical gets tied in, controls get wired, and the thermostat gets set up to run the system the way it's meant to run, including any backup heat if the unit has it. Before anyone leaves, the system gets charged to the manufacturer's spec and run through its paces in both modes, checking temperatures, pressures, and airflow at the vents.