What winter actually asks of a heat pump here
Heat runs eight months a year in Porter County, October through May, and the overnight low averages 20°F across December, January and February. That's the stretch a heat pump has to answer for. A standard heat pump's output falls short of its rating once it's below 40°F outside, and below about 35°F it often needs backup heat to make up the difference. Twenty degrees is under both marks. So is every one of the roughly 125 nights a year here that fall to freezing or below, about half the nights in the heating season.
That doesn't mean the heat pump sits idle on those nights. Field testing of cold-climate heat pumps in occupied homes found backup heat carried only a small share of the load between 0°F and 35°F, and running on backup alone was rare above 0°F. Porter County only reaches 0°F or below about 7 nights a year, a small part of the 125 freezing nights. So the backup heat a heat pump needs here is mostly topping off a system that's still doing most of the work, not replacing it. The ENERGY STAR Cold Climate models are built for exactly this: at 5°F they're rated to still produce 1.75 units of heat for every unit of electricity and hold onto at least 70 percent of their milder-weather capacity. A standard heat pump isn't built to that mark. If you're set on a heat pump here, that's the spec to check for.