What the cold does to a heat pump here
Winter here is long and it runs cold. Heat runs about eight months a year, October through May, and the overnight low in December, January and February averages 22°F. That average is below both marks that matter for a heat pump. Below 40°F a standard heat pump puts out less than its rated capacity. Below about 35°F it often needs backup heat to make up the difference. At 22°F you are under both marks on an average night, not just on the cold ones.
About 115 nights a year here fall at or below freezing, roughly half the nights in the heating season. On those nights a standard heat pump is working below its rating and likely leaning on backup heat to hold the house at temperature. Only about 5 nights a year drop to 0°F or below, so the deep cold is rare, but the ordinary cold that triggers backup heat is not rare at all. It is about half of every winter.
A heat pump built to the ENERGY STAR Cold Climate spec is a different machine on paper. To earn that label it has to make at least 1.75 units of heat for every unit of electricity at 5°F and hold on to at least 70 percent of its 47°F capacity at that same temperature, checked by independent testing. A two-winter study of prototype cold-climate heat pumps in occupied homes found backup heat covered only a small share of the heat needed between 0°F and 35°F, and the system running on backup alone was rare even above 0°F. That is the gap between a standard heat pump and one built for this kind of winter.