What the cold here does to a heat pump
Winter here is long and it gets properly cold. Heat runs about eight months a year, October through May, and the average overnight low in December, January and February is 19°F. About 145 nights a year dip to freezing or below, more than half the nights heat is running at all. A standard heat pump starts losing ground before it even gets that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it usually needs backup heat to make up the difference. Both of those marks sit above the 19°F average low here, and every single one of those 145 freezing nights is colder than both marks too. This is not an occasional cold snap this system has to shrug off. It is most of the heating season.
That does not mean a heat pump will leave you cold. Eight nights a year here reach 0°F or below, a small slice of the 145 freezing nights, and the deep cold that actually stresses a heat pump out is rare, not constant. Cold climate heat pumps are built for exactly this. To earn the ENERGY STAR cold climate label, a unit has to keep making heat efficiently down to 5°F and hold onto most of its capacity at that temperature, verified by outside testing, not the manufacturer's word. In field testing of these units in real homes over two winters, backup heat only covered a small share of the load between 0°F and 35°F, and the unit running on backup alone was rare even above 0°F. So the story changes a lot depending on which heat pump you mean. A standard one, built to the federal minimum, will lean on backup heat for most of a Steuben County winter. A cold climate one is built to avoid exactly that.