What the cold actually does to a heat pump here
Your winters are the whole question. Heat runs eight months a year in Elkhart County, October through May, and the overnight low averages 20°F across December, January and February. That number matters because of where it sits. A standard heat pump's output starts falling short of its rating below 40°F, and somewhere around 35°F it usually needs backup heat to keep up. Twenty degrees is under both marks, and it's not a rare dip. It's the average low for three straight months.
About 130 nights a year here fall at or below freezing, over half of the nights across the whole heating season. Every one of those nights is already below the point where a standard heat pump needs help. So for most of the winter, a heat pump here isn't running alone. It's running alongside a backup heat source, usually electric resistance heat, to make up the difference.
That's not true of every heat pump. Models built to the ENERGY STAR Cold Climate spec have to prove, under third-party testing, that they still make at least 1.75 units of heat per unit of electricity at 5°F and hold onto 70 percent of their 47°F capacity at that temperature. Field tests of prototype cold-climate units found backup heat carried only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. A standard heat pump and a cold-climate one behave differently here, and in a county with 130 freezing nights a year, that difference is the whole decision if a heat pump is on the table at all.