What winter here does to a heat pump
Winter here is long and it gets properly cold. The heat runs eight months a year, October through May, and the overnight low averages 20 degrees across December, January and February. That 20 degrees matters more than the average suggests, because a standard heat pump's output starts falling short of its rating below 40°F, and it often needs backup heat below about 35°F. The average winter night here sits below both marks, not just on the coldest nights but as the normal case.
Over half the nights in heating season, about 135 of them, drop to freezing or below. On every one of those nights a standard heat pump is working below both the 40-degree and 35-degree marks. That's not an occasional cold snap it has to push through. That's most of the season.
The hard cold is a smaller problem than the cold that just sits there. Only about 8 nights a year reach 0°F, and that's the range where a heat pump struggles most. If you want a heat pump to carry a Marshall County winter on its own, look for the ENERGY STAR Cold Climate label. That designation requires the unit to still produce at least 1.75 units of heat per unit of electricity at 5°F and hold onto 70 percent of its 47°F capacity at that temperature, checked by independent testing. A standard heat pump isn't built to do that. A cold-climate one is tested to prove it can.
Backup heat isn't just a theoretical fallback here. In a two-winter field test of prototype cold-climate heat pumps running in occupied homes, backup heat only kicked in for a small share of the heating between 0°F and 35°F, and running on backup alone was rare even above 0°F. That's with cold-climate equipment. A standard heat pump, built to the federal minimum, leans on its backup heat more, and more often, through a winter shaped like this one.