Can a heat pump keep up on the cold nights here
Winter is the long season in Vigo County. Heat runs seven months, October through April, against five months of cooling. Whatever you install spends most of its working life heating this house, not cooling it.
A standard heat pump starts losing ground before it gets especially cold. Below 40°F its heat output falls short of what it's rated for. Below about 35°F it often needs backup heat to make up the difference. The overnight low here averages 23°F across December, January and February, under both marks, and every one of the roughly 115 nights a year that fall to freezing or below is under both marks too. That's over half the nights in the heating season.
This doesn't mean the house goes cold. It means a standard heat pump is leaning on backup heat, usually electric resistance heat, for a lot of the winter, and that backup heat costs more to run than the heat pump itself. The $1.97 per 100,000 Btu figure for a heat pump assumes none of that backup heat at all, so on the coldest nights the real cost runs higher than that number.
A heat pump built to the ENERGY STAR Cold Climate spec is a different machine on paper. To earn that label it has to deliver at least 1.75 units of heat per unit of electricity at 5°F and hold onto 70 percent of its 47°F capacity at that same temperature, verified by outside testing, not the manufacturer's own numbers. In a two-winter field test of prototype cold-climate heat pumps in occupied homes, backup heat covered only a small share of the heat needed between 0°F and 35°F, and the homes almost never ran on backup heat alone above 0°F.
Vigo County sees about 4 nights a year at 0°F or below. That's a small slice of the 115 freezing nights, and it's the range where even a cold-climate heat pump leans hardest on backup. For the other 111 nights, the cold-climate version is built for exactly this county's winter.