What the cold does to a heat pump here
Winters here decide this. Heat runs seven months a year, October through April, and the overnight low averages 24 degrees across December, January and February. That number matters because of where a standard heat pump starts to struggle. Below 40°F it puts out less heat than its rating says. Below about 35°F it often needs backup heat to make up the difference. 24°F is past both marks, and so is almost every winter night here.
About 110 nights a year drop to freezing or below, roughly half the nights across the whole heating season. On those nights a standard heat pump is working below its rating and likely leaning on backup heat to keep the house warm. Only about 3 nights a year reach 0°F, so the deep cold is rare. The ordinary cold is not. It is most of the winter.
A cold-climate heat pump is built for exactly this. To earn the ENERGY STAR Cold Climate label, it has to keep making heat efficiently at 5°F and hold on to most of its rated capacity at that temperature, tested by someone other than the manufacturer. Field tests of these units in occupied homes back that up: backup heat covered only a small share of the load between 0°F and 35°F, and the unit running on backup alone was rare even above 0°F. A standard heat pump is not built to that standard, and this county's winters are built around the range where that difference shows up.