What your winters actually ask of the machine
Your furnace here runs eight months a year, October through May, and for more than half those nights, about 130 of them, it's working against a temperature at or below freezing. The average overnight low across December, January and February is 21°F. That's the real question for a heat pump: not whether it works, but what it's doing on those 130 nights.
A standard heat pump starts falling short of its own rating once it's below 40°F outside, and by about 35°F it typically needs backup heat to keep up. Your winter average of 21°F sits below both marks, and every single one of those 130 freezing nights does too. That doesn't mean the heat pump stops. It means on most nights you run heat here, it's leaning on something else to finish the job, usually electric resistance heat, which costs more to run than the heat pump itself.
There's a version built for this. The ENERGY STAR Cold Climate heat pump has to prove it still makes 1.75 units of heat per unit of electricity at 5°F, and hold onto 70 percent of its milder-weather capacity at that temperature, checked by outside testing. Field tests on homes running these units through two winters found backup heat carrying only a small share of the load between 0°F and 35°F, and almost never carrying the whole load unless it dropped below 0°F. Your county sees that extreme only about 8 nights a year. A standard heat pump is answering the wrong question for a place like this. A cold climate one is answering the right one.