What winter actually asks of the system
Heat runs about eight months a year here, October through May, so whatever you install is working most of the year. The overnight low averages 22°F across December, January and February, and that number matters more than any summer spec. A standard heat pump starts losing ground before it even gets that cold. Below 40°F its heat output comes in under its rating. Below about 35°F it often needs backup heat to keep up. Here, both marks sit above the average winter night, not below it. Out of the roughly 125 nights a year that hit freezing or colder, every one of them is below both marks too.
That does not rule out a heat pump. Cold climate models carry an ENERGY STAR rating that requires them to keep at least 70 percent of their 47°F heating capacity at 5°F, tested by someone other than the manufacturer. Field tests of cold climate models in occupied homes over two winters found backup heat carried only a small share of the total between 0°F and 35°F, and running on backup alone was rare even above 0°F. Putnam County only sees about 6 nights a year at 0°F or below. So the question is not whether a heat pump can handle an occasional cold snap here. It is whether the one you are looking at is built for it. A standard heat pump and a cold climate heat pump are not the same purchase.