What the cold here does to a heat pump
Howard County winters sit right in the range where a standard heat pump struggles. The overnight low averages 21°F across December, January and February, and that's below both marks that matter for a heat pump. Below 40°F its heat output falls short of what it's rated for. Below about 35°F it often needs backup heat to make up the difference. Here, every single night at or below freezing, about 130 of them a year, falls under both marks.
That doesn't mean a heat pump leaves you cold. It means a standard one is leaning on backup heat for more than half the nights of the heating season, and that backup heat is usually electric resistance, the most expensive way to heat a house. A cold-climate heat pump is built for exactly this problem. To earn that label, a unit has to prove it still makes 1.75 units of heat for every unit of electricity at 5°F, and hold onto at least 70 percent of its rated capacity at that temperature, checked by independent testing. Field tests of these units in real homes back it up: backup heat covered only a small share of the heating between 0°F and 35°F, and the units rarely ran on backup alone unless it dropped below 0°F. That only happens about 8 nights a year here. So the question isn't whether a heat pump can handle a Howard County winter. It's whether the one you're looking at is built for it.
A furnace doesn't have this problem, because it doesn't work by moving heat out of cold air. It burns gas and makes heat directly, so a 21°F night or an 8°F night asks nothing extra of it.