What winter here does to a heat pump
Heat runs eight months a year here, October through May. Cooling runs three, June through August. Whatever gets picked is mostly a heating decision, because heating is the season that lasts.
A standard heat pump starts falling behind before the real cold shows up. Below 40°F it puts out less heat than its rating says. Below about 35°F it usually needs backup heat to make up the difference. The average overnight low here in December, January and February is 21°F, under both marks. About 125 nights a year drop to freezing or below, and every one of those nights is under both marks too.
That doesn't mean the house goes cold. It means that on roughly half the nights of the heating season, a standard heat pump is leaning on backup heat to keep up. Six nights a year reach 0°F or below, a small slice of those 125, but it's the slice where a standard heat pump is working hardest for the least return.
There's a version built for this. A heat pump carrying the ENERGY STAR Cold Climate mark has to prove, in third-party testing, that it still makes 1.75 units of heat per unit of electricity at 5°F and holds onto 70 percent of its 47°F capacity at that temperature. Field tests of cold-climate heat pumps in occupied homes back this up: backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. If a heat pump goes into a house here, that's the spec worth asking for. A standard one is not built for this county's winter.