What the cold actually does to a heat pump here
Winter here is long and it gets properly cold. The heat runs eight months a year, October through May, and the overnight low averages 20°F across December, January and February. That 20°F average matters more than it sounds like it should. A standard heat pump starts losing ground below 40°F, putting out less heat than its rating says, and below about 35°F it often leans on backup heat to make up the difference. Here, the average winter night is already past both marks. This isn't a few bad nights a year. About 125 nights a year here drop to freezing or below, roughly half of all the nights the heat is even running, and on every one of those nights a standard heat pump is working below both thresholds.
It does get colder than that. About 6 nights a year reach 0°F or below, a small share of the cold nights but not zero. If you're looking at a heat pump for this county, the ENERGY STAR Cold Climate listing is the thing to check for. To earn it, a heat pump has to keep making at least 1.75 units of heat per unit of electricity at 5°F, and hold onto 70 percent of its warm-weather capacity at that temperature, tested by someone other than the manufacturer. A field test of these cold-climate units over two winters found backup heat covering only a small share of the load between 0°F and 35°F, and the units running on backup alone was rare even above 0°F. A standard heat pump and a cold-climate one are not the same purchase in a county like this.